How to extinguish a lithium-ion battery fire
A lithium-ion battery fire is extinguished with an agent that can reach the burning cells inside the pack, not only knock down visible flames. Ordinary solutions often fail here: gas, for example, does not cool the cells, and the seat of the fire may sit inside a cabinet or a container. The decision is not simply "which extinguisher", but which way to deliver the agent to the source: a portable extinguisher, stand-off delivery, or a module inside the battery pack. Below: why a battery fire is hard to fight, which delivery methods exist, and how to match protection to a site.
Why a lithium-ion battery fire is hard to extinguish
A battery fire starts in one cell. The challenge is the whole system. Three features matter:
- Thermal runaway. Heating in one cell can trigger thermal runaway and transfer heat to neighbouring cells. Flames can be knocked down while the process inside the pack continues.
- The source sits inside the pack. Cells are inside a pack, a cabinet or a container. They are hard to reach from the outside, and opening a burning container is dangerous.
- Monitoring after suppression. Even after visible flames are addressed, a pack may remain hot and require monitoring under site procedures.
The scenario depends on battery chemistry, pack design and site conditions. The same protection is not equally suitable for a UPS room in a data centre and for a warehouse of palletised batteries.
The LiSafe agent
LiSafe is a liquid fire-suppression agent developed for fires involving lithium-containing batteries of any type. It is ready to use and is not diluted with water. Detailed test protocols, conditions and results are provided to interested customers after an NDA.
The product is the agent itself. A portable extinguisher, a stand-off system and an in-pack module are tools for delivering it to the source.
Three delivery methods, and when to use each
- Portable extinguisher. For an initial response by on-site personnel under site procedures. Intended for the batteries themselves and for combustible materials next to them. Typical settings include data centres, depots, factories and warehouses.
- Stand-off delivery. The agent is delivered from a distance defined by the system configuration and site conditions, without people approaching the source. The stated range is up to 120 m and depends on the system configuration. Typical settings include energy storage, depots, ports and warehouses.
- In-pack module. A self-activating module sits inside the battery pack and releases the agent at a defined temperature, without an external signal or power supply. The activation threshold is 90-170 °C. Parameters are selected for the configuration. The design is vibration-resistant.
In practice the methods are often combined: the module works inside the pack, while extinguishers and stand-off delivery give personnel a second line that does not require approaching the source.
Typical site scenarios
Typical scenarios (the configuration is selected for the battery and the site):
- Data centres and telecom: extinguishers at UPS cabinets, a module inside battery packs. A fire in the UPS battery room can take down the whole data centre.
- Energy storage (BESS): a module inside packs, stand-off delivery from outside. A fire in one module can spread to the whole container.
- Battery manufacturing and recycling: extinguishers on the line, stand-off delivery for storage areas.
- EV fleets, depots, charging hubs and car parks: a module inside packs, stand-off delivery, extinguishers for site staff.
- Battery warehouses and Ro-Ro vessels: stand-off delivery up to 120 m, extinguishers for staff and crew.
How a solution is selected
Applicability and the delivery method are agreed for a specific site. The work follows four steps:
- Review the application: battery type, pack layout, site conditions.
- Design the system: the protection format and equipment placement.
- Test the configuration: an agreed scenario on the selected battery.
- Pilot and scale-up: document the results and adapt the project for the site.
For a factual discussion, it helps to have: battery type and chemistry, how the batteries are arranged (cabinet, rack, container, vehicle), whether packs are accessible, and where people are.
FAQ
Can you extinguish a lithium-ion battery with water or with gas?
The LiSafe agent is applied without dilution with water. Gas suppression does not cool the cells, so in thermal runaway the source may flare up again. For battery sites, delivery of the agent to the cells and monitoring of the pack after suppression both matter.
What does the cost of battery protection depend on?
On the type and number of batteries, pack layout, the chosen delivery method (extinguishers, a stand-off system, in-pack modules) and the scope of tests for the site scenario. A precise calculation is made after the application is reviewed. No prices are published in this text.
How can test protocols be obtained?
Send a request to info@lisafe.tech. Detailed protocols, conditions and results are provided to interested customers after an NDA. A demonstration or a pilot can also be discussed.
Will this work for our battery system?
Applicability is confirmed for each project: share the battery type, layout and operating conditions, and a protection format and next step can be proposed.
Can a configuration be tested in a fire test?
Yes. The test scenario is agreed for the site task. A fire test does not replace the documentation of a specific product.
If you want to discuss a site, write to info@lisafe.tech with where the batteries are and what you need to solve.